Please use this identifier to cite or link to this item: http://hdl.handle.net/11701/42583
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorПоленс Александр Анатольевичru_RU
dc.contributor.advisorPolens Aleksandr Anatolevicen_GB
dc.contributor.authorУсмонов Мухаммадсоли Акмалжон углиru_RU
dc.contributor.authorUsmonov Muhammadsoli Akmalzon uglien_GB
dc.contributor.editorСоколович Наталия Александровнаru_RU
dc.contributor.editorSokolovic Natalia Aleksandrovnaen_GB
dc.date.accessioned2023-07-26T12:35:20Z-
dc.date.available2023-07-26T12:35:20Z-
dc.date.issued2023
dc.identifier.other073440en_GB
dc.identifier.urihttp://hdl.handle.net/11701/42583-
dc.description.abstractВ исследовании выпускной квалификационной работы представлена сравнительная оценка размерной точности цифровых трёхмерных технологий и традиционных методик, применяемых в стоматологической практике. В практической части работы сравниваются цифровые оттиски, полученные 3D-сканером и оцифрованные модели, отлитые из оттискных материалов. При проведении исследования применялись оттискные материалы из А-силикона, интраоральный и лабораторный сканеры, компьютерные программы проектирования и производства. Результаты исследования свидетельствуют о том, что цифровые трёхмерные модели, полученные интраоральным сканером обладают высокой размерной точностью и соответствуют предъявляемым к моделям требованиям в клинической практике. На основании проведенного исследования сделан вывод о том, что цифровые трёхмерные модели могут быть использованы наряду с моделями, полученными традиционными оттискными материалами.ru_RU
dc.description.abstractThe study of the graduate qualification work presents a comparative assessment of the dimensional accuracy of digital three-dimensional technologies and traditional techniques used in dental practice. In the practical part of the work digital impressions obtained by 3D-scanner and digitized models cast from impression materials are compared. A-silicone impression materials, intraoral and laboratory scanners, computer-aided design and production programs were used in the study. The results of the study indicate that the digital three-dimensional models obtained with an intraoral scanner have high dimensional accuracy and meet the requirements for models in clinical practice. On the basis of the conducted research the conclusion has been made that the digital three-dimensional models can be used along with the models obtained by traditional impression materials.en_GB
dc.language.isoru
dc.subjectтрёхмерные технологии в стоматологииru_RU
dc.subjectцифровые оттискиru_RU
dc.subjectразмерная точностьru_RU
dc.subjectинтраоральныйru_RU
dc.subjectсканерru_RU
dc.subjectпрограммное обеспечениеru_RU
dc.subject3Dru_RU
dc.subjectCAD/CAMru_RU
dc.subjectКТru_RU
dc.subjectthree-dimensional technologies in dentistryen_GB
dc.subjectdigital impressionsen_GB
dc.subjectdimensional accuracyen_GB
dc.subjectintraoralen_GB
dc.subjectscanneren_GB
dc.subjectsoftwareen_GB
dc.subject3Den_GB
dc.subjectCAD/CAMen_GB
dc.subjectCTen_GB
dc.titleThe application of three-dimensional technologies in dentistryen_GB
dc.title.alternativeПрименение трехмерных технологий в стоматологииru_RU
Appears in Collections:MAIN FIELD OF STUDY

Files in This Item:
File Description SizeFormat 
USMONOV_M.A._PRIMENENIE_TREHMERNYH_TEHNOLOGIJ_V_STOMATOLOGII.docxArticle16,15 MBMicrosoft Word XMLView/Open
USMONOV_M.A._PRIMENENIE_TREHMERNYH_TEHNOLOGIJ_V_STOMATOLOGII.pdfArticle4,71 MBAdobe PDFView/Open
reviewSV_Otzyv.docxReviewSV2,3 MBMicrosoft Word XMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.