Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://hdl.handle.net/11701/42601
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.advisorФеофилов Григорий Александровичru_RU
dc.contributor.advisorFeofilov Grigorij Aleksandrovicen_GB
dc.contributor.authorЕрыгин Илья Игоревичru_RU
dc.contributor.authorErygin Ila Igorevicen_GB
dc.contributor.editorЖеребчевский Владимир Иосифовичru_RU
dc.contributor.editorZerebcevskij Vladimir Iosifovicen_GB
dc.date.accessioned2023-07-26T12:35:23Z-
dc.date.available2023-07-26T12:35:23Z-
dc.date.issued2023
dc.identifier.other077428en_GB
dc.identifier.urihttp://hdl.handle.net/11701/42601-
dc.description.abstractРак - одна из самых опасных и распространенных болезней в мире, требующая эффективных методов диагностики и лечения. В медицине существуют различные методы лечения рака, однако протонная терапия, позволяет достичь локализации практически всей терапевтической дозы на опухоли, минимизируя воздействие на здоровые ткани. Для снижения неопределенности в адаптивном лечении перед проведением сеанса протонной терапии заранее рассчитывается и составляется план дозовых нагрузок для каждого пациента на основе данных о тормозной способности протонов в соответствующих тканях. В настоящее время это достигается за счет рентгеновской компьютерной томографии при преобразовании карт поглощения рентгеновского излучения в тканях, в карты тормозной способности протонов в этих же тканях. Такое преобразование является одним из основных источников неопределенности в оценке положения пика Брэгга. Поэтому при планировании лечения с использованием протонов необходимо использовать протонную компьютерную томографию, которая напрямую восстанавливает трехмерную карту тормозной способности протонов, что позволяет достичь высокой точности при диагностике пациента. Идея протонной визуализации основана на измерении остаточной энергии каждого протона, что позволяет определить тормозную способность ткани вдоль его пути. Для этой цели используется цифровой калориметр, состоящий из слоев Монолитных Активных Пиксельных Сенсоров (МАПС), которые чередуются со слоями поглотителя. Такие пиксельные детекторы отличаются высокой гранулярностью и быстродействием, что делает их лучшим вариантом для применения в протонной томографии. В представленной работе исследовалось идентификационная способность цифрового калориметра, построенного на основе МАПС, для регистрации протонов различных энергий. Для этого проводилось моделирование установки, состоящей из кремниевых пиксельных детекторов и свинцовых поглотителей, через которую проходит пучок протонов. В результате моделирования была дана оценка количеству образующихся вторичных частиц, при прохождении пучка протонов различной энергии через детекторы, свинцовые поглотители и коллиматор. Затем проводилось моделирование экспериментальной установки, после чего результаты сравнивались с данными, полученными в ходе экспериментальных исследований. В итоге было сделано заключение о возможности определения первоначальной энергии пучка по изменению интенсивности частиц пучка в каждом чувствительном слое пиксельных детекторов.ru_RU
dc.description.abstractCancer remains one of the most dangerous and prevalent diseases worldwide, necessitating effective diagnostic and treatment methods. While various cancer treatment approaches exist in the field of medicine, proton therapy has emerged as a promising modality that enables precise targeting of therapeutic doses to tumors while minimizing damage to healthy tissues. To reduce uncertainties in adaptive treatment, a pre-calculated and customized dose plan for each patient is formulated based on proton relative stopping power data in relevant tissues. Currently, this is accomplished by converting X-ray computed tomography images of tissue attenuation into maps of proton relative stopping power, with this conversion being a major source of uncertainty in assessing the position of the Bragg peak. Therefore, proton computed tomography, which directly reconstructs three-dimensional maps of proton stopping power, is crucial in achieving high precision in patient diagnosis and treatment planning. The concept of proton visualization relies on measuring the residual energy of each proton, which allows determination of tissue stopping power along its path. For this purpose, a digital calorimeter consisting of Monolithic Active Pixel Sensors (MAPS) interleaved with absorber layers is employed. Such pixelated detectors offer high granularity and fast response, making them an optimal choice for proton tomography applications. In this study, the identification capability of a digital calorimeter based on MAPS for detecting protons of different energies was investigated. A simulation setup was developed, comprising silicon pixel detectors, lead absorbers, and a beam of protons. The simulation provided an estimate of the number of secondary particles generated when the proton beam of varying energies passed through the detectors, lead absorbers, and collimator. Subsequently, an experimental setup was modeled, and the results were compared with data obtained from experimental investigations. The findings indicated the potential to determine the initial energy of the proton beam by analyzing the intensity variations of beam particles in each sensitive layer of the pixel detectors.en_GB
dc.language.isoru
dc.subjectДетекторы ядерных излученийru_RU
dc.subjectПротонная терапияru_RU
dc.subjectпротонная томографияru_RU
dc.subjectкалориметрru_RU
dc.subjectпиксельный детекторru_RU
dc.subjectNuclear radiation detectorsen_GB
dc.subjectProton therapyen_GB
dc.subjectproton tomographyen_GB
dc.subjectcalorimeteren_GB
dc.subjectpixel detectoren_GB
dc.titleCalorimetry based on pixel detectors for proton tomographyen_GB
dc.title.alternativeКалориметрия с использованием пиксельных детекторов для протонной томографииru_RU
Располагается в коллекциях:BACHELOR STUDIES

Файлы этого ресурса:
Файл Описание РазмерФормат 
VKR_Erygin_Ilya_Igorevich.pdfArticle1,57 MBAdobe PDFПросмотреть/Открыть
reviewSV_Otzyv_Naucnyj_Rukovoditel.pdfReviewSV66,56 kBAdobe PDFПросмотреть/Открыть
reviewSV_st077428_Erygin_Ila_Igorevic_(supervisor)(Ru).txtReviewSV10,97 kBTextПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.