Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://hdl.handle.net/11701/32813
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorShikov, Anton-
dc.contributor.authorTsay, Viktoriya-
dc.contributor.authorFedyakov, Mikhail-
dc.contributor.authorEismont, Yuri-
dc.contributor.authorRudnik, Alena-
dc.contributor.authorUrasov, Stanislav-
dc.contributor.authorSherbak, Sergey-
dc.contributor.authorGlotov, Oleg-
dc.date.accessioned2021-08-20T19:45:39Z-
dc.date.available2021-08-20T19:45:39Z-
dc.date.issued2021-06-
dc.identifier.citationShikov, A., Tsay, V., Fedyakov, M., Eismont, Y., Rudnik, A., Urasov, S., Sherbak, S., and Glotov, O. 2021. The application of Nanopore sequencing for variant calling on the human mitochondrial DNA. Bio. Comm. 66(2): 109–123.en_GB
dc.identifier.otherhttps://doi.org/10.21638/spbu03.2021.202-
dc.identifier.urihttp://hdl.handle.net/11701/32813-
dc.description.abstractThe emergence of long-read sequencing technologies has made a revolutionary step in genome biology and medicine. However, long reads are characterized by a relatively high error rate, impairing their usage for variant calling as a part of routine practice. Thus, we here examine different popular variant callers on long-read sequences of the human mitochondrial genome, convenient in terms of small size and easily obtained high coverage. The sequencing of mitochondrial DNA from 8 patients was conducted via Illumina (MiSeq) and the Oxford Nanopore platform (MinION), with the former utilized as a gold standard when evaluating variant calling’s accuracy. We used a conventional GATK3-BWA-based pipeline for paired-end reads and Guppy basecaller coupled with minimap2 for MinION data, respectively. We then compared the outputs of Clairvoyante, Nanopolish, GATK3, Longshot, DeepVariant, and Varscan tools applied on longread alignments by analyzing false-positive and false-negative rates. While for most callers, raw signals represented false positives due to homopolymeric errors, Nanopolish demonstrated both high similarity (Jaccard coefficient of 0.82) and a comparable number of calls with the Illumina data (140 vs. 154) with the best performance according to AUC (area under ROC curve, 0.953) as well. In sum, our results, despite being obtained from a small dataset, provide evidence that sufficient coverage coupled with an optimal pipeline could make long reads of mitochondrial DNA applicable for variant calling.en_GB
dc.language.isoenen_GB
dc.publisherSt Petersburg State Universityen_GB
dc.relation.ispartofseriesBiological Сommunications;Volume 66; Issue 2-
dc.subjectnext-generation sequencingen_GB
dc.subjectOxford Nanoporeen_GB
dc.subjectIlluminaen_GB
dc.subjectvariant callingen_GB
dc.subjectmitochondrial DNAen_GB
dc.titleThe application of Nanopore sequencing for variant calling on the human mitochondrial DNAen_GB
dc.typeArticleen_GB
Располагается в коллекциях:Issue 2

Файлы этого ресурса:
Файл Описание РазмерФормат 
109-123.pdf5,58 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.