Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://hdl.handle.net/11701/29868
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorTregubov, Vladimir P.-
dc.contributor.authorEgorova, Nadezhda K.-
dc.date.accessioned2021-07-14T13:29:59Z-
dc.date.available2021-07-14T13:29:59Z-
dc.date.issued2021-06-
dc.identifier.citationTregubov V. Р., Еgorova N. К. Investigation of the frequency properties of a standard linear body. Vestnik of Saint Petersburg University. Applied Mathematics. Computer Science. Control Processes, 2021, vol. 17, iss. 2, pp. 166-17З.en_GB
dc.identifier.otherhttps //doi.org/10.21638/11701/spbu10.2021.206-
dc.identifier.urihttp://hdl.handle.net/11701/29868-
dc.description.abstractIt is known that the Кelvin-Voigt model does not describe stress relaxation, which is observed along with elastic properties in many polymers and biomaterials. In this regard, the standard linear body model is used to describe the properties of these materials. Studies of its properties were mainly limited to the study of its reaction to an instantaneously applied load, as well as to the determination of the time and nature of stress relaxation. Аt the same time, the frequency properties of the standard linear body remained unexplored. In this regard, an analysis of its frequency properties was carried out, which made it possible to study its behavior under vibration exposure. Оn the basis of the equation of motion, the amplitude-frequency response (АFC) was constructed, and its peculiarity was revealed, which consists in the fact that an increase in the damping coefficient leads to a decrease in the maximum value of the АFC only to a certain value greater than one. А further increase in the damping coefficient leads to an increase in the maximum frequency response up to infinity at a frequency that should also be considered resonant. Thus, the frequency response of a standard linear body always has a maximum. The subsequent increase in the damping coefficient leads to the tendency of the maximum frequency response to zero at infinity.en_GB
dc.language.isoruen_GB
dc.publisherSt Petersburg State Universityen_GB
dc.relation.ispartofseriesVestnik of St Petersburg University. Applied Mathematics. Computer Science. Control Processes;Volume 17; Issue 2-
dc.subjectstandard linear bodyen_GB
dc.subjectfrequency responseen_GB
dc.subjectmodel parametersen_GB
dc.subjectuniqueness of parameter valuesen_GB
dc.titleInvestigation of the frequency properties of a standard linear bodyen_GB
dc.typeArticleen_GB
Располагается в коллекциях:Issue 2