Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://hdl.handle.net/11701/35582
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorKhilchuk, Anton A.-
dc.contributor.authorPayvin, Artyom A.-
dc.contributor.authorScherbak, Sergey G.-
dc.contributor.authorGuryev, Valentin V.-
dc.contributor.authorKarmazanashvili, Evgeniy G.-
dc.date.accessioned2022-03-09T20:11:46Z-
dc.date.available2022-03-09T20:11:46Z-
dc.date.issued2021-09-
dc.identifier.citationKhilchuk A. A., Payvin A. A., Scherbak S. G., Guryev V. V., Karmazanashvili E. G., Lazakovich D. N. CT-fusion-guided thoracic endovascular aortic repair: Case report and literature review. Vestnik of Saint Petersburg University. Medicine, 2021, vol. 16, issue 3, pp. 180–189.en_GB
dc.identifier.otherhttps://doi.org/10.21638/spbu11.2021.305-
dc.identifier.urihttp://hdl.handle.net/11701/35582-
dc.description.abstractInterventional and hybrid methods of treatment, combining open surgical and endovascular repairs, are the most promising areas in the surgery of the thoracoabdominal aorta. Recent studies, however, have demonstrated that complex thoracic endovascular aneurysm repair (TEVAR) is one of the most high-dose endovascular interventions. In addition, TEVAR is associated with the use of a significant volume of contrast media (CM), which can lead to contrast-induced acute kidney injury (CI-AKI). The use of advanced imaging techniques and computed tomographic fusion (CT-fusion) in routine practice can potentially reduce operation duration, radiation exposure and CM volume usage. We analyzed the literature on CTfusion in endovascular aortic repair and present a clinical case of a 50-year-old male with a history of concomitant blunt chest trauma. CT of the chest revealed an aneurysm of the arch and descending aorta after traumatic dissection of the aorta (IIIa DeBakey, type B Stanford), post-traumatic diaphragmatic hernia of the left dome of the diaphragm with stomach and intestinal loops prolapse. The patient underwent a staged hybrid intervention — subtotal aortic arch debranching followed by CT-fusion-guided semi-arch TEVAR. CT-fusion is a dynamically developing technology, may reduce the CM volume, the duration of the procedure and radiation exposure and requires further research.en_GB
dc.language.isoenen_GB
dc.publisherSt Petersburg State Universityen_GB
dc.relation.ispartofseriesVestnik of St Petersburg University. Medicine;Volume 16; Issue 3-
dc.subjectaortaen_GB
dc.subjectendovascular aortic repairen_GB
dc.subjectaortic aneurysmen_GB
dc.subjectcomputed tomographyen_GB
dc.subjectCT‑fusionen_GB
dc.titleCT-fusion-guided thoracic endovascular aortic repair: Case report and literature reviewen_GB
dc.typeArticleen_GB
Располагается в коллекциях:Issue 3

Файлы этого ресурса:
Файл Описание РазмерФормат 
180-189.pdf1,5 MBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.