Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: http://hdl.handle.net/11701/2050
Полная запись метаданных
Поле DCЗначениеЯзык
dc.contributor.authorYaroshenko, Irina-
dc.contributor.authorKirsanov, Dmitry-
dc.contributor.authorKartsova, Lyudmila-
dc.contributor.authorSidorova, Alla-
dc.contributor.authorBorisova, Irina-
dc.contributor.authorLegin, Andrey-
dc.date.accessioned2016-04-11T08:08:27Z-
dc.date.available2016-04-11T08:08:27Z-
dc.date.issued2015-01-
dc.identifier10.1016/j.talanta.2014.08.030-
dc.identifier.issn10.1016/j.talanta.2014.08.030-
dc.identifier.urihttp://hdl.handle.net/11701/2050-
dc.description.abstractThe ionic composition of urine is a good indicator of patient's general condition and allows for diagnostics of certain medical problems such as e.g., urolithiasis. Due to environmental factors and malnutrition the number of registered urinary tract cases continuously increases. Most of the methods currently used for urine analysis are expensive, quite laborious and require skilled personnel. The present work deals with feasibility study of potentiometric multisensor system of 18 ion-selective and cross-sensitive sensors as an analytical tool for determination of urine ionic composition. In total 136 samples from patients of Urolithiasis Laboratory and healthy people were analyzed by the multisensor system as well as by capillary electrophoresis as a reference method. Various chemometric approaches were implemented to relate the data from electrochemical measurements with the reference data. Logistic regression (LR) was applied for classification of samples into healthy and unhealthy producing reasonable misclassification rates. Projection on Latent Structures (PLS) regression was applied for quantitative analysis of ionic composition from potentiometric data. Mean relative errors of simultaneous prediction of sodium, potassium, ammonium, calcium, magnesium, chloride, sulfate, phosphate, urate and creatinine from multisensor system response were in the range 3-13% for independent test sets. This shows a good promise for development of a fast and inexpensive alternative method for urine analysis.en_GB
dc.language.isoenen_GB
dc.titleDetermination of urine ionic composition with potentiometric multisensor systemen_GB
dc.typeArticleen_GB
Располагается в коллекциях:Articles

Файлы этого ресурса:
Файл Описание РазмерФормат 
2015-Urine-Talanta.pdf545,46 kBAdobe PDFПросмотреть/Открыть


Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.