Please use this identifier to cite or link to this item: http://hdl.handle.net/11701/26451
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorКолпак Евгений Петровичru_RU
dc.contributor.advisorKolpak Evgenij Petrovicen_GB
dc.contributor.authorЧуракова Алёна Сергеевнаru_RU
dc.contributor.authorCurakova Alena Sergeevnaen_GB
dc.contributor.editorКотина Елена Дмитриевнаru_RU
dc.contributor.editorKotina Elena Dmitrievnaen_GB
dc.date.accessioned2021-03-24T15:26:45Z-
dc.date.available2021-03-24T15:26:45Z-
dc.date.issued2020
dc.identifier.other054217en_GB
dc.identifier.urihttp://hdl.handle.net/11701/26451-
dc.description.abstractВ данной работе решается задача вычисления поля скоростей в цифровой обработке последовательности изображений. Рассматриваются два классических метода, а также комбинация локального и глобального методов. Последний совмещает в себе подходы обоих техник вычисления. В таком случае оптический поток является плотным, но при этом менее подвержен влиянию шумов, благодаря введению сглаживающего члена уравнения. Учитывая описанные преимущества, последний метод используется для нахождения векторного поля в последовательности радионуклидных изображений. Применение методов оптического потока в области радионуклидных исследований является актуальным, поскольку они позволяют выполнять автоматическую коррекцию движения, так как даже небольшое смещение человека или исследуемого органа во время сбора данных может повлиять на правильность результатов. Полностью избежать движения невозможно, поскольку проведение исследования некоторых органов может занимать довольно много времени. В результате проделанной работы предложены алгоритмы обработки изображений с использованием пирамиды изображений; разработана программа и проведены тесты на различных изображениях, в том числе радионуклидных.ru_RU
dc.description.abstractIn this paper, we solve the problem of estimating the velocity field in the digital processing of an image sequence. Two classical methods are considered, as well as a combination of local and global methods. The latter combines the approaches of both techniques. In this case, the optical flow is dense, but less sensitive to noise due to the introduction of a smoothing term of the equation. Taking into account the described advantages, the latter method is used to compute a vector field in a sequence of radionuclide images. The application of optical flow methods in radionuclide studies is relevant because they allow automatic correction of a movement since even a small displacement of a person or an organ under investigation during data collection can affect the correctness of the results. It is impossible to completely avoid a movement since the study of some organs can take quite a lot of time. As a result of the work done, image processing algorithms using the image pyramid are proposed; a program was developed and tests were conducted on various images, including radionuclide ones.en_GB
dc.language.isoru
dc.subjectоптический потокru_RU
dc.subjectполе скоростейru_RU
dc.subjectметод Лукаса-Канадеru_RU
dc.subjectметод Хорна-Шанкаru_RU
dc.subjectкомбинация методовru_RU
dc.subjectрадионуклидные изображенияru_RU
dc.subjectпирамида изображенийru_RU
dc.subjectoptical flowen_GB
dc.subjectvelocity fielden_GB
dc.subjectLucas–Kanade methoden_GB
dc.subjectHorn–Schunck methoden_GB
dc.subjectcombination of methodsen_GB
dc.subjectradionuclide imagesen_GB
dc.subjectpyramidal approachen_GB
dc.titleAnalysis of image processing algorithms based on the optical flow methoden_GB
dc.title.alternativeАнализ алгоритмов обработки изображений на основе метода оптического потокаru_RU
Appears in Collections:BACHELOR STUDIES

Files in This Item:
File Description SizeFormat 
VKR.pdfArticle1,55 MBAdobe PDFView/Open
reviewSV_Otzyv_naucnogo_rukovoditela.pdfReviewSV358,64 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.