dc.description.abstractThe simple and easy performed flow system based on sandwich technique has been developed for the simultaneous separate determination of iron (II) and ascorbic acid in pharmaceuticals. The implementation of sandwich technique assumed the injection of sample solution between two selective reagents and allowed the carrying out in reaction coil two chemical reactions simultaneously: iron (II) with 1,10-phenanthroline and ascorbic acid with sodium 2,6-dichlorophenolindophenol. For achieving of excellent repeatability and considerable reagent saving the various parameters such as flow rate, sample and reagent volumes, reaction coil length were also optimized. The limits of detection (LODs) obtained by using the developed flow sandwich-type approach were 0.2 mg L(-1) for iron (II) and 0.7 mg L(-1) for ascorbic acid. The suggested approach was validated according to the following parameters: linearity and sensitivity, precision, recoveries and accuracy. The sampling frequency was 41 h(-1).en_GB
dc.description.sponsorshipThis work was supported by the Russian Foundation for Basic Research (project No. 13-03-00031-a). Scientific researches were performed at the Center for chemical analysis and materials research of St. Petersburg State University.en_GB
dc.language.isoenen_GB
dc.publisherElsevieren_GB
dc.subjectAutomation of pharmaceutical analysisen_GB
dc.subjectFlow analysisen_GB
dc.subjectSandwich techniqueen_GB
dc.subjectIron (II)en_GB
dc.subjectAscorbic aciden_GB
dc.titleSimultaneous determination of iron (II) and ascorbic acid in pharmaceuticas based on flow sandwich techniqueen_GB